Principle:
Transit-time ultrasonic flowmeter
Accuracy:
Accuracy :over 1%-2%; Repeatability: over 0.2%
Display :
4 line x 16 character LCD with backlight
Dimension:
200*93*33cm: 390g
Operation:
Support 16 key light touch keyboard and the Simulation keyboard software
Data interface:
Insulate RS232 serial interface, upgrade the flew meter software by computer, support the MODBUS, etc.
Signal Output:
1 way OCT output
Special Cable :
Twisted-pair cable, ;Select the RS232 communication
Pipe Material :
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.
Pipe Diameter :
DN25-6000mm
Straight length pipe:
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump.